Airborne Labs International
  • Home
    • About Us
    • Leadership
    • Our Worldwide Presence
    • Industry Accreditations & Involvement
    • Press & Presentations
    • Sampling Videos
    • Contact Us
  • Analytical Lab Services
    • CO2 Analysis Programs
    • Industrial Commodity Gases
    • ABO & Air Analysis
    • SF6 Test Programs
    • Specialized Gases
    • Hydrogen Fuel
    • NFPA-99 Gas Distribution System Validation
    • Customer R&D Project Support
    • On-Site Sampling Services
    • Sampling Videos
  • Gas Sampling/Equipment
    • CO2 Sampling Equipment & Supplies
    • Commodity Gas Sampling Equipment & Supplies
    • Breathing Air Sampling & Aviation Oxygen
    • SF6 Gas Sampling Equipment & Supplies
    • Passivated Gas Sampling Hardware
  • Gas Analyzers
    • Air Separation Analyzers
    • Detector Tube-Based Gas Analyzers
    • CO2 Purity & Sensory Testing Equipment
    • Continuous, On-Line Gas Quality Analyzers
    • Turn Key, Integrated Gas Analyzer Systems
  • Gas Detector Tubes
  • Gas Standards
  • Shop
    • Cart
    • Quotes
    • Checkout
  • Client Portal
    • Register for an Account
Home / Gas Analyzers / Analyzers / Total Hydrocarbon Analyzer 9000
Total Hydrocarbon Analyzer 9000

Total Hydrocarbon Analyzer 9000

Request a Quote
Category: Analyzers
  • Description

Description

For performance of ISBT Method 10.0 THC content of bev-grade CO2 and other gas applications. The Model 9000 Total Hydrocarbon Analyzer (FID) System with Automatic Calibration Control.

  • 1 Point (Span/Zero/Sample)
  • 5 programmable relay outputs
  • 4-20 mA analog outlet
  • RS-232
  • Ethernet digital outputs
  • 9000 Keeper Software Package
  • Methods Manuals included

Insturment Requirements

Power:

  • Requires 90 – 230VAC, 50-60 Hz.

Fuel Gases:

  • Hydrogen fuel gas (Ultra Pure)
    • 30 psig delivery
    • 35 cc/min (Electronic Flow Controlled)
  • zero-grade air flow
    • 30 psig
    • 175 cc/min flow (Electronic Flow Controlled)

Basic CO2 software method is pre-programmed by Airborne Labs International as default. Certified laboratory back-up testing also available for result confirmation.

Detector: Flame Ionization Detector (FID)
Ranges: User definable based upon calibration within:    MDQ 0.01ppm, full-scale 1-200 ppm (Methane) MDQ 0.1ppm, full-scale 1-2,000ppm (Methane) MDQ 0.3ppm, full-scale 1-20,000ppm (Methane)                                                    MDQ 0.003%, full-scale 0.01-100% (Methane)
Repeatability: ± 1% full-scale response
Drift: ± 1% of full-scale over 24 hours
Response Time: < 5 seconds to 90% of final reading
Alarms: Multilevel concentration and fault alarms that result in audible and visual alarms. Alarms may also be mapped to relays to control external equipment
Sampling: Internal single or multipoint modules, for pre-filtered (<0.1 microns) non-condensing samples, with or without sample pump

Optional Accessories:

  • Hydrogen Generator
  • Zero Air Generator
  • Digitial Flow Meter
  • Hydrogen Leak Detector
  • Certified Gas Standards
  • Pressure Regulators and transfer lines

Related products

  • BAM-8900

    BAM-8900

    Request a Quote
  • GAS-1P System Package

    GAS-1P System Package

    Request a Quote
  • SulfAlert-1 TSC Package

    SulfAlert-1 TSC Package

    Request a Quote
  • Oxygen Trace Analyzer (3000TA)

    Oxygen Trace Analyzer (3000TA)

    Request a Quote
© Airborne Labs International, All Rights Reserved        Terms & Conditions ... Privacy Policy ... Opt-Out Policy.
Web Site Design & Development by a3i
Manage Cookie Consent
To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behavior or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Functional Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
Manage options Manage services Manage {vendor_count} vendors Read more about these purposes
View preferences
{title} {title} {title}