Airborne Labs International
  • Home
    • About Us
    • Leadership
    • Our Worldwide Presence
    • Industry Accreditations & Involvement
    • Press & Presentations
    • Sampling Videos
    • Contact Us
  • Analytical Lab Services
    • CO2 Analysis Programs
    • Industrial Commodity Gases
    • ABO & Air Analysis
    • SF6 Test Programs
    • Specialized Gases
    • Hydrogen Fuel
    • NFPA-99 Gas Distribution System Validation
    • Customer R&D Project Support
    • On-Site Sampling Services
    • Sampling Videos
  • Gas Sampling/Equipment
    • CO2 Sampling Equipment & Supplies
    • Commodity Gas Sampling Equipment & Supplies
    • Breathing Air Sampling & Aviation Oxygen
    • SF6 Gas Sampling Equipment & Supplies
    • Passivated Gas Sampling Hardware
  • Gas Analyzers
    • Air Separation Analyzers
    • Detector Tube-Based Gas Analyzers
    • CO2 Purity & Sensory Testing Equipment
    • Continuous, On-Line Gas Quality Analyzers
    • Turn Key, Integrated Gas Analyzer Systems
  • Gas Detector Tubes
  • Gas Standards
  • Shop
    • Cart
    • Quotes
    • Checkout
  • Client Portal
    • Register for an Account
Home / Gas Analyzers / Analyzers / TSC-6200E
TSC-6200E
TSC-6200E 2

TSC-6200E

Highlights:

  • Total Sulfur Content (TSC)
Request a Quote
Category: Analyzers
  • Description

Description

The Model 6200E Total Sulfur Analyzer for continuous monitoring of TSC in CO2 as per ISBT Method 13.0. Includes an Oxidative Converter Module and an Analysis Module that are 19″ Rack Mount configuration.

Ranges: 0 – 50 ppb to 0 – 20,000 ppb full-scale, user selectable; dual ranges and auto-ranging supported
Zero Noise: < 0.2 ppb
Span Noise: < 0.5% of reading (above 50 ppb)
LDL: 0.4 ppb
Zero Drift: <0.5 reading / 24 hours; 1 ppb / 7 days
Span Drift: <0.5% reading / 24 hours; 1% of reading / 7 days
Lag Time: 20 seconds
Rise Time (95%): < 120 seconds
Linearity: 1% of full scale
Sample Flow Rate: 700 cc/min ± 10%
Converter Temperature: 1000°C
Converter Efficiency: > 98% above 0°C dewpoint
Converter Life: 3000 ppm hours
SOx Scrubber Efficiency: > 98%
SOx Scrubber Life: > 1000 ppm hours
Operating Temperature: 5 to 40°C
Power: 100 VAC or 240 VAC, 50/60 Hz (user specified)
Outputs: Analog: 10V, 5V, 1V, 100mV (selectable)
(4 – 20 mA isolated output optional)
RS232 (I\O): Standard DB9
Digital Status: 12 contact closure outputs
Size (H x W x D): Model 6200E analyzer:
(7″ x 17″ x 23.5″) (177.8 x 432 x 596.9 mm)
Dilutor / Converter Module:
(7″ x 17″ x 23.5″) (177.8 x 432 x 596.9 mm)
Calibration Module:
(5.25″ x 17″ x 23.5″) (133.3 x 432 x 596.9 mm)

Support Gases:

  • Hydrogen Carrier gas (Ultra Pure) Fuel Gases:
  • Zero Air
    • Requires dry zero-air support gas at 450 cc/min

Basic CO2 software method is pre-programmed by Airborne Labs International as default. Certified laboratory back-up testing also available for result confirmation.

Optional Accessories:

  • Hydrogen Generator
  • Zero Air Generator
  • Digitial Flow Meter
  • Hydrogen Leak Detector
  • Certified Gas Standards
  • Pressure Regulators and transfer lines

Related products

  • NOx Analyzer

    NOx Analyzer

    Request a Quote
  • Total Hydrocarbon Analyzer 4020

    Total Hydrocarbon Analyzer 4020

    Request a Quote
  • Oxygen Trace Analyzer (3000TA)

    Oxygen Trace Analyzer (3000TA)

    Request a Quote
  • Oxygen Trace Analyzer Aii

    Oxygen Trace Analyzer Aii

    Request a Quote
© Airborne Labs International, All Rights Reserved        Terms & Conditions ... Privacy Policy ... Opt-Out Policy.
Web Site Design & Development by a3i
Manage Cookie Consent
To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behavior or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Functional Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
Manage options Manage services Manage {vendor_count} vendors Read more about these purposes
View preferences
{title} {title} {title}